Bluelab
Maestro Nutrient Controller
Stress relief for you and your crop! Relax. Bluelab Maestro is on the job, with a simple and reliable crop management system that not only monitors nutrient, pH and temperature levels, but also controls dosing. Starting to feel better already?
The Bluelab Maestro saves you time by doing the work for you, money by
ensuring the right amount of nutrient is used without costly wastage and
constant tank dumping, and guesswork by maintaining and delivering the crucial
levels of nutrient, pH and temperature, required for optimum plant growth
and health. When plants are supplied with the correct levels, plant stress
is minimized, which ensures consistent growth rates with improved yields.
The Bluelab Maestro simplifies your growing system so you can spend more
time maintaining abundant growth.
Main
Features
-
Independently adjustable CF, EC, ppm (EC x 500), pH and Temperature required values
-
Displays required values continuously and connected Bluelab monitors display the actual values
-
Solenoid Dosing system supplied
-
Peristaltic Pumps dosing option is available
-
A simple relay connection is available for controlling temperature (air or nutrient)
-
Variable temperature differential
-
Can work with one, two or all three Bluelab monitors connected to control either Nutrient, pH or Temperature
-
On time and off time dosing for different tank sizes
-
1 CF (0.1 EC) and 0.1 pH dosing differential
-
Safety lock outs to stop over-dosing
-
Large 13mm (1/2") digital display for easy reading
-
Available in 110V & 240V
-
2 year Bluelab Guarantee
The Bluelab Maestro is supplied as a complete control kit ready to connect to your growing system. Please see the instruction manual for a list of contents and further information.
| Specifications | bluelab maestro |
||
| Nutrient | pH | Temperature | |
| Range | 0.1–9.9 EC 1–99 CF 0–4990 ppm (500) |
2.0–9.9 pH | 0–60°C 32–140°F |
| Resolution | 0.1 EC 1 CF 100 ppm (500) |
0.1 pH | 1°C 2°F |
| Accuracy | 4% of reading | ±0.1 pH | ±1°C ±2°F |
| Control Range | 0.2–9.5 EC 2–95 CF 100–4750 ppm (500) |
4.0–8.0 pH | 2–99°C 36–210°F |
| Temperature Compensation | automatic temperature compensation | not applicable | not applicable |
| Calibration | factory calibrated | manual calibration | factory calibrated |
| Temperature Differential | not applicable | not applicable | 0–9° differential |
| Power Supply | 110V 240V | ||
| Operating Temperature Range | 0–50°C 32–122°F | ||